Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
West J Emerg Med ; 22(3): 547-551, 2021 Apr 19.
Artículo en Inglés | MEDLINE | ID: covidwho-1266883

RESUMEN

INTRODUCTION: The coronavirus 2019 pandemic caused a shortage of disposable N95 respirators, prompting healthcare entities to extend the use of these masks beyond their intended single-use manufacturer recommendation with a paucity of supporting research. METHODS: We performed a prospective cohort study of ED healthcare workers (HCW) ("subjects") required to use respirators at an academic, Level I trauma center. Subjects had been previously fit tested and assigned an appropriately sized N95 mask per hospital protocol. Per study protocol, subjects were fit tested periodically throughout their shifts and on multiple shifts over the eight-week study period. Data points collected included the age of the mask, subjective assessment of mask seal quality, and fit test results. We analyzed the data using Fisher's exact test, and calculated odds ratios (OR) to determine the failure rate of disposable N95 masks following reuse. RESULTS: A total of 130 HCWs underwent fit testing and 127 were included for analysis. Mask failure rate climbed after day 2 of use, with 33.3% of masks failing at day 3, 42.9% at day 4, and 50% at ≥ day 5. Categorizing the masks into those being used for two or fewer days vs those in use for three or more, failure was more common on day 3 of use or older compared to those in the first two days of use (41.8% vs 8.3%, P < 0.0001) with an OR of failure with an older mask of 7.9 (confidence interval [CI], 2.8-22.3). The healthcare workers' assessment of poor seal was 33.3% sensitive (CI, 18.6-51.9) and 95.7% specific (CI, 88.8-98.6) for fit test failure. CONCLUSION: Disposable N95 masks have significant failure rates following reuse in clinical practice. Healthcare personnel also performed poorly in assessing the integrity of the seal of their disposable respirators.


Asunto(s)
Falla de Equipo/estadística & datos numéricos , Equipo Reutilizado , Respiradores N95 , COVID-19/epidemiología , COVID-19/prevención & control , Equipos Desechables , Servicio de Urgencia en Hospital , Humanos , Pandemias , Estudios Prospectivos
3.
J Intensive Care Med ; 36(5): 604-611, 2021 May.
Artículo en Inglés | MEDLINE | ID: covidwho-999444

RESUMEN

BACKGROUND: Patients with COVID-19 and ARDS on prolonged mechanical ventilation are at risk for developing endotracheal tube (ETT) obstruction that has not been previously described in patients with ARDS due to other causes. The purpose of this report is to describe a case series of patients with COVID-19 and ARDS in which ETT occlusion resulted in significant clinical consequences and to define the pathology of the obstructing material. METHODS: Incidents of ETT occlusion during mechanical ventilation of COVID-19 patients were reported by clinicians and retrospective chart review was conducted. Statistical analysis was performed comparing event rates between COVID-19 and non-COVID 19 patients on mechanical ventilation over the predefined period. Specimens were collected and submitted for pathological examination. FINDINGS: Eleven COVID-19 patients experienced endotracheal tube occlusion over a period of 2 months. Average age was 69 (14.3, range 33-85) years. Mean APACHE III score was 73.6 (17.3). All patients had AKI and cytokine storm. Nine exhibited biomarkers for hypercoagulability. Average days on mechanical ventilation before intervention for ETT occlusion was 14 (5.18) days (range of 9 to 23 days). Five patients were discharged from the ICU, and 4 expired. Average documented airway resistance on admission was 14.2 (3.0) cm H2O/L/sec. Airway resistance before tube exchange was 28.1 (8.0) cm H2O /L/sec. No similar events of endotracheal tube occlusion were identified in non-COVID patients on mechanical ventilation during the same time period. Microscopically, the material consisted of mucin admixed with necrotic cell debris, variable numbers of degenerated inflammatory cells, oral contaminants and red blood cells. INTERPRETATION: Patients with COVID-19 and ARDS on prolonged mechanical ventilation are at risk for developing ETT obstruction due to deposition of a thick, tenacious material within the tube that consists primarily of mucin and cellular debris. Clinicians should be aware of this dangerous but treatable complication.


Asunto(s)
Obstrucción de las Vías Aéreas , COVID-19/complicaciones , Intubación Intratraqueal , Respiración Artificial , Síndrome de Dificultad Respiratoria , APACHE , Anciano , Obstrucción de las Vías Aéreas/etiología , Obstrucción de las Vías Aéreas/patología , Obstrucción de las Vías Aéreas/terapia , COVID-19/epidemiología , COVID-19/terapia , Duración de la Terapia , Falla de Equipo/estadística & datos numéricos , Femenino , Humanos , Intubación Intratraqueal/efectos adversos , Intubación Intratraqueal/instrumentación , Masculino , Mortalidad , Respiración Artificial/instrumentación , Respiración Artificial/métodos , Respiración Artificial/estadística & datos numéricos , Síndrome de Dificultad Respiratoria/etiología , Síndrome de Dificultad Respiratoria/mortalidad , Síndrome de Dificultad Respiratoria/terapia , Retratamiento/métodos , Retratamiento/estadística & datos numéricos , Estudios Retrospectivos , SARS-CoV-2 , Resultado del Tratamiento , Estados Unidos/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA